APPLICATIONS

Point of Use - high end or aesthetic

Point of Use - low end or not apparent

Boiler control (hot water storage boiler)

Solar applications

Group installation, 1 to 5 outlets, flow up to 42 l/min

Group installation, large multiple outlet (1 to 50 outlets), flow up to 400 l/min

Group installation high flow, or industrial application, flow up to 1200 l/min

Points requiring special attention

Group installation, 1 to 5 outlets, flow up to 42 l/min

T9715 - 1/2" B (white body) or C (chromed)

T9107 - 3/4" B (white body) or C (chromed)



FEATURES

Comfort : the water temperature obtained is accurate to within one degree. Individually checked in the factory, Trubert mixing valves must be calibrated before first use. An exclusive knob mounting system makes this calibration easy. Temperature regulation and stability are excellent, regardless of variations in pressure (max. 1.5 bar), mixing valve inlet temperature and flow rate.

Extremely straightforward to install : no special tools are required ; the hot water inlet is fitted on the left, with the mixed water outlet in vertical position. Trubert mixing valves can be placed in various positions without making the temperature difficult to read...

Scald protection : the hot water is rapidly cut if the cold water supply is interrupted.

Very easy maintenance : the durability and scale resistance of Trubert mixing valves ensure that maintenance is virtually nil. The cartridge can be easily replaced without dismantling the mixing valve.



Simple to install. Economical to use.




PURPOSE

Recommended for all applications where the mixed water temperature must be kept exact and constant,
and adjusted at any time.

Bathroom applications with low flow rate : showers, basins...
Electronic tap - Industrial uses - Chilled water applications



OPTIONS

Designed to adapt to all specific demands for water at a precise temperature, even at very low flow rate.
Several setting ranges : 15/50°C or 40/80°C or 0/40°C.



PROTECTION AGAINST LEGIONELLA

Cartridge can be removed and replaced (for easier scale removal and disinfecting).
Integral approved check-valves (withstanding temperatures above 90°C).
Various thermal flash possibilities : use in the 40/80°C range or remove the temperature knob
---and turn the cartridge to the maximum hot position allowing the water to flow at a hot temperature.





Top of page